Automated, accurate and reproducible results for liver shear wave elastography

Automate your liver elastography exams with Auto ElastQ: precision, reproducibility and ease of use – all in one solution! Auto ElastQ automatically analyzes elastography loops and selects frames for measurement within a 2D shear wave elastography (ElastQ) image. It also recommends measurement locations within these selected frames. The liver stiffness measurements obtained from liver shear wave elastography can be used to diagnose and stage patients with liver fibrosis.

Auto ElastQ

Watch a side-by-side comparison to see how Auto ElastQ saves time and exam steps

Auto ElastQ is faster than conventional ElastQ and requires significantly fewer manual steps. Watch the video to see how they compare.

Demonstrated results with Auto ElastQ

  1. 60%

    faster

    60%

    faster

    Auto ElastQ can reduce liver shear wave elastography exam time by up to 60%.*

  2. 99%

    reliability

    99%

    reliability

    Auto ElastQ offers 99% reliability of automated acquired liver shear wave measurements.*

  3. 29%

    fewer steps

    29%

    fewer steps

    Auto ElastQ can reduce the number of steps to acquire liver shear wave measurements by up to 29%.*

Frame selection
Elastography measurements should be made on frames that show stable and consistent shear wave propagation. Auto ElastQ identifies and selects these stable frames by comparing each frame to its neighbors and choosing only those frames that are very similar to adjacent frames and have a high percentage of fill inside the ElastQ imaging box.
Auto ElastQ UI
Quality metrics
Auto ElastQ analyzes the ElastQ image based on three quality metrics: smoothness within each local region, temporal stability of each region relative to the same regions in adjacent frames and the similarity of each pixel relatively to the rest of the pixels inside the box. This ensures that the region of interest is placed in a location that is representative of the majority of the pixels in the ElastQ imaging box.
Auto ElastQ quality metrics
ROI selection
The three quality metrics are combined into one composite map. The peak in this composite map, along with the confidence map, is used to select the region of interest for measurement.
Auto ElastQ scan showing region of interest selection